Review and modify to conform to C99 integer types format specifiers.
Use arm-none-eabi toolchain to build successfully.
Change-Id: If855072a8f88886809309155ac6d031dcfcbc4b2
Signed-off-by: Hsiangkai Wang <hsiangkai@gmail.com>
Signed-off-by: Hsiangkai <hsiangkai@gmail.com>
Reviewed-on: http://openocd.zylin.com/1794
Tested-by: jenkins
Reviewed-by: Spencer Oliver <spen@spen-soft.co.uk>
Previously, when doing EMU_CMD_HW_JTAG3 commands we would do two reads,
one to read the data, and one to read the result. However, we can just
do a single larger read instead.
The motivation for this change is a weird problem. If I run the Segger
software before running OpenOCD, then the first read always fails:
Error: usb_bulk_read failed (requested=1, result=0)
Error: jlink_tap_execute, wrong result -107 (expected 1)
Sniffing the USB traffic shows that the J-Link is returning an
overflow error, meaning it is expecting to return the full result
in a single read.
Change-Id: I75e020d3b3732c9a74ee3d31838fdf17a7fac24c
Signed-off-by: Philip Craig <phil@blackmoth.com.au>
Reviewed-on: http://openocd.zylin.com/1447
Tested-by: jenkins
Reviewed-by: Xiaofan <xiaofanc@gmail.com>
Reviewed-by: Spencer Oliver <spen@spen-soft.co.uk>
jtag_interface.transports field was left uninitialized, which triggers warning message
on program startup.
Although hardware natively supports SWD interface, no software support
currently present, so the value choosen to be <jtag_only>.
Change-Id: I2da41790b1850950af416cec4362d5b7bf927b2b
Signed-off-by: Alexander Osipenko <sipych@gmail.com>
Reviewed-on: http://openocd.zylin.com/670
Tested-by: jenkins
Reviewed-by: Xiaofan <xiaofanc@gmail.com>
Reviewed-by: Spencer Oliver <spen@spen-soft.co.uk>
Some versions of Segger's software do not select JTAG interface by default.
Do it in the intial setup.
Firmware version check code still present, with updated set of unsupported.
Note from Segger:
Alright, we were not aware of that OpenOCD does not select the interface
before it starts communicating with the target. A debugger should always
select the appropriate target interface before it starts communicating with the target,
since otherwise it could also happen that a previous session with another debugger
had selected SWD and the interface was not switched again by OpenOCD.
Change-Id: I5b4eab7e0e3625ec32be75a36d89e16d17e899bf
Signed-off-by: Alexander Osipenko <sipych@gmail.com>
Reviewed-on: http://openocd.zylin.com/667
Tested-by: jenkins
Reviewed-by: Xiaofan <xiaofanc@gmail.com>
Reviewed-by: Spencer Oliver <spen@spen-soft.co.uk>
jlink_usb_io() function added for basic communication,
since jlink_usb_message() is more specific to JTAG transactions.
To verify the patch issue "jlink config" command.
Change-Id: Id7d10bd5e8985d4c77f2e0ca47fb6033db2877bf
Signed-off-by: Alexander Osipenko <sipych@gmail.com>
Reviewed-on: http://openocd.zylin.com/679
Tested-by: jenkins
Reviewed-by: Xiaofan <xiaofanc@gmail.com>
Reviewed-by: Spencer Oliver <spen@spen-soft.co.uk>
OpenOCD does not work with the latest firmware versions
of Segger J-Link.
Latest working version: V4.42c
Unsupported versions: 4.44 to 4.46f, 4.20 to 4.30
Older versions of firmware can be found here:
http://www.segger.com/j-link-older-versions.html
The firmware versions does not correspond directly with
"Software and documentation pack for Windows", it may be
distinguished by the "compile" date in the information string.
Print an warning message if unsupported firmware version detected.
Change-Id: Id7d1f965b8ce2fdbcd0026a85ddd093e2fa48720
Signed-off-by: Alexander Osipenko <sipych@gmail.com>
Reviewed-on: http://openocd.zylin.com/666
Tested-by: jenkins
Reviewed-by: Xiaofan <xiaofanc@gmail.com>
Reviewed-by: Spencer Oliver <spen@spen-soft.co.uk>
jlink modified to use the new usb abstaction layer.
During the configuration process we can select if use
libusb0 or libusb-1.0 library for this driver.
Change-Id: I70bc9ee2f89b7597e0f64ea80cad7f1b9070f01b
Signed-off-by: Mauro Gamba <maurillo71@gmail.com>
Reviewed-on: http://openocd.zylin.com/236
Tested-by: jenkins
Reviewed-by: Xiaofan <xiaofanc@gmail.com>
Reviewed-by: Spencer Oliver <spen@spen-soft.co.uk>
as said in the datasheet Section 3.3.2 Organization of buffers
All buffers are big enough to hold 2 KByte of data.
this will double the speed of download
Signed-off-by: Jean-Christophe PLAGNIOL-VILLARD <plagnioj@jcrosoft.com>
Cc: Nicolas Ferre <nicolas.ferre@atmel.com>
Cc: Patrice Vilchez <patrice.vilchez@atmel.com>
this will allow us to use multiple jlink at the same time as when
the USB-Address is specified the PID change from 0x0101 to
(0x101 + usb_adress)
Signed-off-by: Jean-Christophe PLAGNIOL-VILLARD <plagnioj@jcrosoft.com>
The default pid of the segger is 0x0101
But when you change the USB Address it will also
pid = ( usb_address > 0x4) ? 0x0101 : (0x101 + usb_address)
Signed-off-by: Jean-Christophe PLAGNIOL-VILLARD <plagnioj@jcrosoft.com>
it will allow to be at the highest speed of the jlink without touching the
board or cpu config
tested on sam-ice v5 and at91rm9200-ek
Signed-off-by: Jean-Christophe PLAGNIOL-VILLARD <plagnioj@jcrosoft.com>
Cc: Nicolas Ferre <nicolas.ferre@atmel.com>
Cc: Patrice Vilchez <patrice.vilchez@atmel.com>
If the JTAG speed has not been set, then it has no defined
value, add code to propagate the error.
No change to actual behavior as no new failure paths have
been introduced. This is a no-op patch to make subsequent patches
smaller.
Signed-off-by: Øyvind Harboe <oyvind.harboe@zylin.com>
JTAG_MOVESTATE is misleading, this cmd is only used
for reset.
JTAG_PATHMOVE should be used otherwise.
Signed-off-by: Øyvind Harboe <oyvind.harboe@zylin.com>
Segger publishes some documentation on this protocol;
reference it, so future maintainers can know it exists.
Signed-off-by: David Brownell <dbrownell@users.sourceforge.net>
Changes from the flat namespace to heirarchical one. Instead of writing:
#include "interface.h"
the following form should be used.
#include <jtag/interface.h>
The exception is from .c files in the same directory.
Changes from the flat namespace to heirarchical one. Instead of writing:
#include "commands.h"
the following form should be used.
#include <jtag/commands.h>
The exception is from .c files in the same directory.
Moves JTAG interface drivers to src/jtag/drivers/,
Adds src/jtag/drivers/Makefile.am.
Builds libocdjtagdrivers.la.
Flattens the rlink driver files into the drivers/ directory, adding
the 'rlink_' prefix or '.rlink' suffix as appropriate.