Previously, when doing EMU_CMD_HW_JTAG3 commands we would do two reads, one to read the data, and one to read the result. However, we can just do a single larger read instead. The motivation for this change is a weird problem. If I run the Segger software before running OpenOCD, then the first read always fails: Error: usb_bulk_read failed (requested=1, result=0) Error: jlink_tap_execute, wrong result -107 (expected 1) Sniffing the USB traffic shows that the J-Link is returning an overflow error, meaning it is expecting to return the full result in a single read. Change-Id: I75e020d3b3732c9a74ee3d31838fdf17a7fac24c Signed-off-by: Philip Craig <phil@blackmoth.com.au> Reviewed-on: http://openocd.zylin.com/1447 Tested-by: jenkins Reviewed-by: Xiaofan <xiaofanc@gmail.com> Reviewed-by: Spencer Oliver <spen@spen-soft.co.uk> |
||
---|---|---|
.. | ||